Hello,It's been awhile since I've asked a question here but I need some of this community's expertise yet again. I am connecting an a two story addition to an existing home. …
Hello,A duplex I recently purchased has a moist crawlspace including moist brick and water-stained mudsill (see pictures). I believe most of the problem comes from missing or poorly placed downspouts. …
Hello,I have a 1920s duplex that has a large old growth mudsill. The inspection report said that a few parts of the mudsill had some moisture damage. The reason for…
I am finally ready to insulate my basement with closed cell spray foam. I have the choice between Icynene, Demilec Heatlok HT HFO, or Lapolla Foam Lok 2000-4G. The latter…
So I talked to an LG engineer today (hint: if you have questions about minisplit performance, don't call tech support, find the number to a local manufacturer and ask to…
Hello, I have an LG ductless minisplit system. The condenser is an LG LMU480HV. There are 8 indoor units (6 wall units, 2 ceiling mounts) connected to the condenser. The…
I believe I have solved my problem of why my ductless minisplit system was performing so poorly. My condenser was overcharged with refrigerant by 3 lbs. I have attached a…
One of the Passivhaus standards is that total energy usage including appliances cannot exceed 11.1 kwh per sq. ft. per year. If I have a 2800 square foot house, then…
It's been about 1 year and 10 months since I started building my house and I'm still grinding. Doing the board and batten siding mixed with cedar is taking some…
I apologize for the clickbait title, but it seems all of the insulation contractors in my area are very wary of dense-packed cellulose in walls and often say, "we normally…
Recent Q&A
Putting batt insulation between 2×4 top chord truss for unvented low slope roof
Hello,It's been awhile since I've asked a question here but I need some of this community's expertise yet again. I am connecting an a two story addition to an existing home. …
Closed cell spray foam over moist brick and mudsill
Hello,A duplex I recently purchased has a moist crawlspace including moist brick and water-stained mudsill (see pictures). I believe most of the problem comes from missing or poorly placed downspouts. …
关闭细胞喷雾泡沫在旧μdsill
Hello,I have a 1920s duplex that has a large old growth mudsill. The inspection report said that a few parts of the mudsill had some moisture damage. The reason for…
HFOs vs. HFCs in spray foam
I am finally ready to insulate my basement with closed cell spray foam. I have the choice between Icynene, Demilec Heatlok HT HFO, or Lapolla Foam Lok 2000-4G. The latter…
Turning off/setting back ductless minisplits, kwh, efficiency, and more
So I talked to an LG engineer today (hint: if you have questions about minisplit performance, don't call tech support, find the number to a local manufacturer and ask to…
Phantom Load – Ductless Minisplit
Hello, I have an LG ductless minisplit system. The condenser is an LG LMU480HV. There are 8 indoor units (6 wall units, 2 ceiling mounts) connected to the condenser. The…
Overcharged minisplit condenser leads to higher electricity bills
I believe I have solved my problem of why my ductless minisplit system was performing so poorly. My condenser was overcharged with refrigerant by 3 lbs. I have attached a…
Passivhaus total energy usage standard
One of the Passivhaus standards is that total energy usage including appliances cannot exceed 11.1 kwh per sq. ft. per year. If I have a 2800 square foot house, then…
Still Grinding – Uninsulated basement and minisplit problems
It's been about 1 year and 10 months since I started building my house and I'm still grinding. Doing the board and batten siding mixed with cedar is taking some…
Dense-packed cellulose might go extinct
I apologize for the clickbait title, but it seems all of the insulation contractors in my area are very wary of dense-packed cellulose in walls and often say, "we normally…